BIO-CIDE
Part No: 1043
This liquid scale and corrosion inhibitor is designed for use in both hot or cold water, closed loop recirculating systems. It features a phosphate-based formula with a polymer dispersant for anti-precipitating and sequestering harmful hardwater scale. It can be injected directly into the recirculating system through the use of a bypass feeder, or applied by use of mild steel piping and feeding equipment.
TECHNICAL SPECS
Packing Type : Gallons
BOILER COMPLETE TREAT H
Part No: 1045
This liquid additive features a multifunctional formula with alkalinity builders, oxygen scavengers, sludge dispersants and corrosion inhibitors to offer superior water treatment, especially in hard-water systems. It also travels along with the steam in the system to protect steam and condensate plumbing and it operating in top condition
TECHNICAL SPECS
Packing Type : gallons
BOILER COMPLETE TREAT S
Part No: 1047
This soft water steam boiler treatment features a multifunctional formula with all of the necessary chemicals for complete treatment in one convenient liquid. It combines hardness control with oxygen scavengers and a volatile amine corrosion inhibitor that travels along with the steam to protect both the steam and condensate plumbing. It can be used on a “one-shot” basis, or with an automated continuous feed system, and is safe to use with other boiler treatment chemicals.
TECHNICAL SPECS
Packing Type : Gallons
BOILER TREAT H
Part No: 1049
This liquid additive was designed to prevent the deposition of lime, scale, rust and other minerals in large water treatment boilers. It is especially effective for boilers that use hard water. It can be used in conjunction with automated feed systems, or mixed with other boiler treatment chemicals on a weekly maintenance schedule.
TECHNICAL SPECS
Packing Type : -
BOILER TREAT S
Part No: 1051
This liquid steam boiler additive is a phosphate-based cycle treatment fortified with a proven polymeric scale inhibitor. It was designed for use in soft-water environments and can be used on a “one-shot” basis or with an automated continuous feed system. It is safe to use with other boiler treatment chemicals, especially steam line treatments and oxygen scavengers.
TECHNICAL SPECS
Packing Type : Gallons
FUEL TREAT
Part No: 1053
This liquid additive is designed for use in fuel systems where problems occur in the storage tank, as well as at fireside. It reduces the viscosity of all types of fuel oils and creates a fluidizing effect to promote faster pumping. As a result, fuel oil burns cleaner and more completely, which in turn reduces emission problems. It also forms a protective film on the internal surfaces of storage tanks and piping to reduce corrosion and deposit build-up.
TECHNICAL SPECS
Packing Type : Gallons
LOOP TREAT NITRO
Part No: 1055
This liquid scale and corrosion inhibitor is designed for use in both hot or cold water closed loop recirculating systems. It features a borate/nitrate formula for superior scale and corrosion inhibition, with easy testing and control. It can be injected directly into the recirculating system through the use of a bypass feeder, or applied by use of mild steel piping and feeding equipment.
TECHNICAL SPECS
Packing Type : Gallons
OXY TREAT
Part No: 1057
This liquid is a catalyzed oxygen scavenger that quickly removes dissolved oxygen from boiler feedwater. It also provides additional protection against pitting and corrosion of internal boiler surfaces when used in conjunction with scale and corrosion inhibitors. Plus, it can be mixed with other treatment products and fed into the feed water system, or fed directly into the boiler.
TECHNICAL SPECS
Packing Type : Gallons
SLUDGE TREAT
Part No: 1059
This liquid steam boiler treatment is a non-phosphate dispersant and scale inhibitor designed for use as a supplement to chelant, carbonate or phosphate treatments. It removes and controls scale and other deposits caused by calcium, magnesium, barium, aluminum and iron. It also acts as a polymeric sludge conditioner and fluidizer, and won’t degrade in high temperatures like other dispersants.
TECHNICAL SPECS
Packing Type : Gallons
STEAM TREAT
Part No: 1061
This liquid was formulated to provide corrosion protection in steam boiler condensate systems and other associated power equipment. Regular usage provides a pH adjustment to the untreated steam condensate and prevents the formation of harmful acids. It also provides protection to return lines and reduces the iron and copper content of the condensate.
TECHNICAL SPECS
Packing Type : Gallons
TOWER TREAT H
Part No: 1062
This liquid scale and corrosion inhibitor is specifically formulated for open recirculating cooling tower systems in areas of high hardness and high alkalinity scaling waters. It also contains an additional polymer designed to help inhibit scale and deposition in a wide variety of aqueous systems
TECHNICAL SPECS
Packing Type : Gallons
TOWER TREAT S
Part No: 1064
This liquid scale and corrosion inhibitor is specifically formulated for open recirculating cooling tower systems in areas of low hardness, low alkalinity and highly corrosive scaling waters. It also contains an additional polymer dispersant designed to ensure sludge and scale are easily removed from the system through a regular bleed-off program.